0

    AT Series - Specs

    Analytical Balaneces

    ATX84

    Capacity

    82 g

    Minimum display

    0.1 mg

    Repeatability (Standard deviation)

    ≤0.1 mg

    Linearity

    ±0.2 mg

    Stabilisation Time*1

    Approx. 3.0 seconds

    Operating Temperature and Humidity Limits

    5-40°C 20-85%*2

    Temperature Coefficient for Sensitivity (10-30°C)

    ±2ppm/°C

    Pan Size (mm) approx.

    Φ91

    Main Body Dimensions (mm) approx.

    213(W) x 356(D) x 338(H)

    Main Body Weight (kg) approx.

    6.2

    Power requirement

    12V, 1A

    *1 The Stabilisation time is a representative value
    *2 No condensation

    Read more
    Show Less

    ATX124

    Capacity

    120 g

    Minimum display

    0.1 mg

    Repeatability (Standard deviation)

    ≤0.1 mg

    Linearity

    ±0.2 mg

    Stabilisation Time*1

    Approx. 3.0 seconds

    Operating Temperature and Humidity Limits

    5-40°C 20-85%*2

    Temperature Coefficient for Sensitivity (10-30°C)

    ±2ppm/°C

    Pan Size (mm) approx.

    Φ91

    Main Body Dimensions (mm) approx.

    213(W) x 356(D) x 338(H)

    Main Body Weight (kg) approx.

    6.2

    Power requirement

    12V, 1A

    Read more
    Show Less

    ATX224

    Capacity

    220 g

    Minimum display

    0.1 mg

    Repeatability (Standard deviation)

    ≤0.1 mg

    Linearity

    ±0.2 mg

    Stabilisation Time*1

    Approx. 3.0 seconds

    Operating Temperature and Humidity Limits

    5-40°C 20-85%*2

    Temperature Coefficient for Sensitivity (10-30°C)

    ±2ppm/°C

    Pan Size (mm) approx.

    Φ91

    Main Body Dimensions (mm) approx.

    213(W) x 356(D) x 338(H)

    Main Body Weight (kg) approx.

    6.2

    Power requirement

    12V, 1A

    Read more
    Show Less

    ATX324

    Capacity

    320 g

    Minimum display

    0.1 mg

    Repeatability (Standard deviation)

    ≤0.1 mg

    Linearity

    ±0.2 mg

    Stabilisation Time*1

    Approx. 3.0 seconds

    Operating Temperature and Humidity Limits

    5-40°C 20-85%*2

    Temperature Coefficient for Sensitivity (10-30°C)

    ±2ppm/°C

    Pan Size (mm) approx.

    Φ91

    Main Body Dimensions (mm) approx.

    213(W) x 356(D) x 338(H)

    Main Body Weight (kg) approx.

    6.2

    Power requirement

    12V, 1A

    Read more
    Show Less

    ATY64

    Capacity

    62 g

    Minimum display

    0.1 mg

    Repeatability (Standard deviation)

    ≤0.1 mg

    Linearity

    ±0.2 mg

    Stabilisation Time*1

    Approx. 3.0 seconds

    Operating Temperature and Humidity Limits

    5-40°C 20-85%*2

    Temperature Coefficient for Sensitivity (10-30°C)

    ±2ppm/°C

    Pan Size (mm) approx.

    Φ91

    Main Body Dimensions (mm) approx.

    213(W) x 356(D) x 338(H)

    Main Body Weight (kg) approx.

    6.0

    Power requirement

    12V, 1A

    Read more
    Show Less

    ATY124

    Capacity

    120 g

    Minimum display

    0.1 mg

    Repeatability (Standard deviation)

    ≤0.1 mg

    Linearity

    ±0.2 mg

    Stabilisation Time*1

    Approx. 3.0 seconds

    Operating Temperature and Humidity Limits

    5-40°C 20-85%*2

    Temperature Coefficient for Sensitivity (10-30°C)

    ±2ppm/°C

    Pan Size (mm) approx.

    Φ91

    Main Body Dimensions (mm) approx.

    213(W) x 356(D) x 338(H)

    Main Body Weight (kg) approx.

    6.0

    Power requirement

    12V, 1A

    Read more
    Show Less

    ATY224

    Capacity

    220 g

    Minimum display

    0.1 mg

    Repeatability (Standard deviation)

    ≤0.1 mg

    Linearity

    ±0.2 mg

    Stabilisation Time*1

    Approx. 3.0 seconds

    Operating Temperature and Humidity Limits

    5-40°C 20-85%*2

    Temperature Coefficient for Sensitivity (10-30°C)

    ±2ppm/°C

    Pan Size (mm) approx.

    Φ91

    Main Body Dimensions (mm) approx.

    213(W) x 356(D) x 338(H)

    Main Body Weight (kg) approx.

    6.0

    Power requirement

    12V, 1A

    Read more
    Show Less

    ATY324

    Capacity

    320 g

    Minimum display

    0.1 mg

    Repeatability (Standard deviation)

    ≤0.1 mg

    Linearity

    ±0.2 mg

    Stabilisation Time*1

    Approx. 3.0 seconds

    Operating Temperature and Humidity Limits

    5-40°C 20-85%*2

    Temperature Coefficient for Sensitivity (10-30°C)

    ±2ppm/°C

    Pan Size (mm) approx.

    Φ91

    Main Body Dimensions (mm) approx.

    213(W) x 356(D) x 338(H)

    Main Body Weight (kg) approx.

    6.0

    Power requirement

    12V, 1A

    Read more
    Show Less

    ATX84

    Capacity

    82 g

    Minimum display

    0.1 mg

    ATX124

    Capacity

    120 g

    Minimum display

    0.1 mg

    ATX224

    Capacity

    220 g

    Minimum display

    0.1 mg

    ATX324

    Capacity

    320 g

    Minimum display

    0.1 mg

    ATX84

    Capacity

    62 g

    Minimum display

    0.1 mg

    ATY124

    Capacity

    120 g

    Minimum display

    0.1 mg

    ATY224

    Capacity

    220 g

    Minimum display

    0.1 mg

    ATY324

    Capacity

    320 g

    Minimum display

    0.1 mg